| | CIRCUIT BREAKER, VACUUM; POWER; 23KV; 2000A; 25KA INTRPTNG; OUTDOOR; DEAD TANK | | |
| | PIPE; SEAMLESS; SIZE 3 IN DIA X 35 IN L; SCH 80 WL THK; ALUMINUM | | |
| | RELAY; TRANSFORMER DIFFERENTIAL PROTECTION; PN: P6457CRF6U0220P; 48VDC; MODEL: MICOM P645; MFR: GENERAL ELECTRIC | | |
| | CONTROLLER; REAL TIME AUTOMATION; PN: 3555#BJ7D; MFR: SEL | | |
| | RELAY, CONTROL; PROTECTION AUTOMATION; PN: 0421715X3600XD7H584D4XXXXX; 125VDC; MODEL: 421-7; MFR: SEL | | |
| | BATTERY, DRY CELL, RECHARGEABLE, LEAD ACID, 12V, 25AH | | |
| | DATA-CONCENTRATOR ORIONLXM CAT#4S-S1S1S1S1-IO-WR-2RU1-01-03-04-07-14-37-44-49-57-35-95-99-108-110 NOVATECH | | |
| | DATA-CONCENTRATOR ORIONLXPLEN CAT#PBG-NC1H-HVHV-04-07-14-37-49-57-35-95-99-108 NOVATECH | | |
| | PIPE; SEAMLESS; SIZE SCH 80 X 5 IN DIA X 40FT L; ALUMINUM | | |
| | RELAY, CONTROL; OVERCURRENT PROTECTION AUTOMATION; PN: 451,04516 XX 01400 XE73422 XXXXXX; 48/125VDC; 5A/1A; -40 TO 185DEG F; MFR: SEL; BAY CONTROL SYSTEM | | |
| | BATTERY, LEAD ACID; STATIONARY VENTED; 200AH; 2.23V/BLOCK | | |
| | RELAY; DISTRIBUTION PROTECTION; PN: 751,751401AA01A0 X 850631; SIZE 5.67 IN X 7.56 IN X 5.8 IN; 110/240VAC, 110-250VDC; 50-60HZ; -40 TO 185DEG F; MFR: SEL | | |
| | SWITCH, DISCONNECT; 38KV; 600A | | |
| | BATTERY, DRY CELL; RECHARGEABLE SEALED LEAD ACID; 52AH; 12V | | |
| | CHARGER, BATTERY; 240VAC, 125VDC; 30A; 1 PHASE | | |
| | CIRCUIT BREAKER, VACUUM; POWER; 23KV, 27KV; 1200A CONTINUOUS MAX; OUTDOOR | | |
| | ENCLOSURE; SWITCHGEAR; RMU 5-BAY | | |
| | CIRCUIT BREAKER, GAS; POWER; 145KV; 2000A; 40KA INTRPTNG; SF6, INTERRUPTER | | |
| | SWITCHGEAR; 3 PHASE; 15KV; 95KV BIL; 600A; PAD MNT | | |
| | SWITCH, DISCONNECT; HOOKSTICK OPERATED; 38KV; 2000A | | |
| | BASE, ELECTRICAL; INSULATING; FOR ARRESTER 120KV | | |
| | PLUG; END; PN: ACBIH30; SIZE 3 IN DIA; ALUMINUM; MFR: ANDERSON; WELDMENT | | |
| | PIPE; SEAMLESS; SIZE SCH 80 X 3 IN DIA X 40FT L; ALUMINUM | | |
| | SWITCH, DISCONNECT; MOTOR-OPERATED, DOUBLE SIDE BREAK; 69KV; 2000A; VERTICAL-CONFIGURATION | | |
| | SWITCH, DISCONNECT; DOUBLE SIDE BREAK; 69KV; 2000A; MANUAL-OPERATED VERTICAL-CONFIGURATION | | |
| | RELAY; BUS DIFFERENTIAL OVERCURRENT AND BREAKER FAILURE PROTECTION; PN: 487B; 300V, 24-28VDC, 48-125VAC OR 110-120VAC, 125-250VDC OR 110-240VAC; 5A, 1A; -40 TO 185DEG F; MFR: SEL; DATA RATE: 100 MBPS, RANGE: 2 KM, PROTOCOL: SEL T-PROTOCOL | | |
| | RELAY; TRANSFORMER DIFFERENTIAL PROTECTION; PN: 387A,0387A0203 X 4 X 341; 125VDC; MFR: SEL | | |
| | ARRESTER; SURGE STATION-TYPE; POLYMER; 60KV; 48KV-MCOV | | |
| | SWITCH, DISCONNECT; HOOKOPERATED; PN: LCO-C; 23KV; 1200A; MFR: CLEAVELAND PRICE | | |
| | | | |
| | BUSBAR; BAR BUS; 4 IN W; 3/8 IN THK; COPPER | | |
| | CIRCUIT BREAKER, GAS; POWER; 72.5KV; 2000A; 40KA INTRPTNG; SF6, INTERRUPTER | | |
| | SWITCH, DISCONNECT; HOOKSTICK OPERATED; 15KV; 2000A; MFR: ROYAL-SWITCHGEAR | | |
| | BASE, ELECTRICAL; EXTENDED; SIZE 24 IN; HOT DIP GALVANIZED; FOR 69KV POLYMER POST INSULATOR | | |
| | CABLE; MOLD-TO-GROUND; SIZE: 5/8 IN-ROD; 4/0-WIRE; PN:GTC-162Q; CADWELD | | |
| | BASE, ELECTRICAL; EXTENDED; SIZE 4FT; HOT DIP GALVANIZED; FOR POST INSULATOR | | |
| | ADHESIVE; SEALING-GUM; SIZE 2LB; VIRGINIA | | |
| | | | |
| | MOLDING; HORIZONTAL-X; PN: XBM-2Q2Q; SIZE 4/0-4/0; MFR: CADWELD | | |
| | LIGHTER; FLINT; PN: T320A; MFR: CADWELD | | |
| | TEE; MOLD HORIZONTAL; PN: TAC2Q2Q; SIZE 4/0-4/0, 0.528 IN OD; CADWELD | | |
| | WELDING, EXOTHERMIC; CADWELD, METAL; SIZE #115 | | |
| | WELDING, EXOTHERMIC; CADWELD, METAL; SIZE #150 | | |
| | WELDING, EXOTHERMIC; CADWELD, METAL; SIZE #250 | | |
| | BREAKER, CIRCUIT; POWER DEAD TANK AIR INSULATED OUTDOOR; VACUUM; 15KV, 110KV BIL; 1200A; 3 PH | | |
| | BREAKER, CIRCUIT; POWER DEAD TANK AIR INSULATED OUTDOOR; VACUUM; 15KV, 110KV BIL; 2000A; 3PH | | |
| | AF SENSOR FIBER LOOP- SEL C804 (C80420V30XX) | | |
| | CONNECTOR TEE ALUMINUM WELDMENT TUBE-TO-TUBE 3"DIA-MAIN 3"DIA-TAP CAT#WTT3030 ANDERSON | | |
| | CONNECTOR COUPLER ELBOW ALUMINUM WELDMENT TUBE-TO-TUBE 3"DIA X 3"DIA 90° CAT#WLIH903030 ANDERSON | | |
| | CONNECTOR BUS-SUPPORT ALUMINUM TUBE-TO-INSULATOR VERTICAL 3”DIA 3”BOLT-CIRCLE CAT#AUDE303 ANDERSON | | |
| | CONNECTOR BUS-SUPPORT ALUMINUM TUBE-TO-INSULATOR 3”DIA 3”BOLT-CIRCLE CAT#AUR303 ANDERSON | | |
| | CONNECTOR TEE ALUMINUM WELDMENT NON-TRANSVERSE TUBE-TO-FLAT-TERMINAL 3'”DIA X 1-1/8”T-TERMINAL 4-HOLE CAT#WTTFR3060D ANDERSON | | |
| | CONNECTOR TEE ALUMINUM WELDMENT NON-TRANSVERSE TUBE-TO-FLAT-TERMINAL 3"DIA X 5/8”T-TERMINAL 2-HOLE CAT#WTTFR3060B2 ANDERSON | | |
| | TERMINAL LUG ALUMINUM WELDMENT TUBE-TO-FLAT 3"DIA 4-HOLE CAT#WSTF30D ANDERSON | | |
| | 13.8kV OVERCURRENT RELAYS - MULTILIN F60 (F60-UL3-HLH-FXX-H85-MXX-P6L-UXX-WRL) | | |
| | 69kV AND 13.8kV BUS DIFFERENTIAL - MULTILIN B30 (B30-UOL-HLH-FXX-H85-LXX-N6A-SXX-UXX-WRL) | | |
| | BACK-UP LINE PROTECTION - MiCOM P546 (P5469CNC6R0800P) | | |
| | | | |
| | MERGING UNITS - Reason MU320 (MU3203OB3B4B4XXP5P5BX04SE) | | |
| | SWITCHES - PROCESS BUS - REASON S20 (S202433P2PKCCHHH07C0) | | |
| | SWITCHES - STATION BUS - REASON S20 (S202433P2PKIIHHH07C0) | | |
| | TRANSFORMER DIFFERENTIAL PROTECTION - MULTILIN T60 (T60-UGB-HLH-FXX-H85-MXX-P6L-UXX-WRL) | | |